Recordall ZA 2500

Item number: ZA2500

Anschluss
Typ

starting from 555,00 €

Excluding 19% VAT. , Your order is free shipping.

There are variations of this item. Please select the variation you wish.


Recordall ZA 2500

Highlights:

  • Nylon-version suitable for demineralised water
  • positive displacement meter

Industries/Application areas:
Measuring of demineralised water
Dosing of chemicals

Measuring principle:
The top and lower part of the meter chamber are spherical shaped. A ball bearing centralizes the disc between the two spherical cups. A nutating motion of the disc is generated when flow enters the meter chamber. Complete separation between inlet and outlet chamber volumes is always achieved by one dedicated disc diameter line. The inlet and outlet parts of the meter chamber are separated by a partition plate. The positioning bar forces the disc to nutate around the centre axis of the chamber thus driving the transmission magnet.

Installation/ Maintenance instructions
Make sure that the arrow on the meter housing shows in flow direction. Inlet and outlet straight pipe runs are not necessary. All mounting positions possible.

Housingarmatur: Buna or Viton
Output: optional pulse output
Connection: R 3/4 up to R 1 1/4
Pressure: max. 16 bar
Measuring range: see price sheet
Media: liquid
Process temperature: 0 - +50 °C, bei Vectra 0 - +120 °C
Measuring accuracy: 1,50%
Einbaulänge: see data sheet
Authorisation: without
Contact
Question on item


Price sheet DE

Data sheet DE

Data sheet EN

Manual DE

Manual EN